Book a dive

on Aster by Orque

Tools/Trimix blend
Tx

Trimix blend: the right bottom mix

The ideal bottom trimix for your dive: little enough O₂ to stay under your ppO₂, enough helium to keep a clear head, and a gas that is not too dense.

1

Your dive

The planned maximum depth.

Max depth
m
2

Your limits

The oxygen you accept at depth and the narcosis you tolerate.

Max ppO₂ at depth1.2 to 1.4 bar on trimix
bar
Target ENDnarcosis equivalent to air at…
m

Is oxygen narcotic?

Minimum ppO₂ (hypoxic floor)

Gas density at depth

Reference table

Recommended mix at each depth with ppO₂ 1.40, END 30 m, density ≤ 6.2 g/L. Tap a row to use it.

DepthMixFloorDensity
30 mNx 35surface5.3
40 mTx 28/9surface6.0
50 mTx 23/25surface6.1
60 mTx 20/38surface6.2
70 mTx 17/48surface6.1
80 mTx 15/551 m6.2
90 mTx 14/622 m6.1
100 mTx 12/674 m6.1
110 mTx 11/715 m6.1
120 mTx 10/746 m6.2

Floor: depth from which the mix provides enough O₂. Density at depth: blue ≤ 5.2 g/L, orange up to 6.2 g/L, red above.

Mix to order

Tx20/38

Normoxic
Oxygen20%
exact 20.0
Helium38%
exact 37.4
Nitrogen42%
exact 42.6

At depth, 60 m (7.0 bar)

ppO21.40bar
target max 1.40
END (N₂)27m
target 30 m
ppN22.94bar
ppHe2.66bar
Gas density6.2g/L
increased work of breathing
Floor (ppO₂ 0.16)0m
breathable at the surface
O2set by your ppO₂ 1.40
ENDmet
Densitysets the helium

Fairly dense gas

6.2 g/L: breathing is harder under exertion. Below 5.2 g/L is more comfortable.

Helium added for density

Your END alone gave Tx 20/35; it takes 38 % helium to stay under 6.2 g/L. The actual END drops to 27 m.

Nearest standard gasTx 18/45

ppO₂ 1.26 · END 23 m · 5.6 g/L · floor surface
A little more helium than needed, but it is probably the gas your club or fill station already has.

Usable range of this mix

010203040506070depth (m)your dive 60 m

Usable from 0 m to 60 m (ppO₂ 0.16 to 1.40). MOD at 1.4: 60 m · contingency at 1.6: 70 m.

too little O₂usablebeyond your max ppO₂
How it is calculated

1. Oxygen sets the ceiling

At maximum depth, we put the most O₂ that respects your ppO₂:

P abs = depth ÷ 10 + 1; FO₂ = max ppO₂ ÷ P abs

2. Nitrogen sets the narcosis

We keep as much nitrogen as air contains at your END depth, no more:

FN₂ = 0.79 × (END ÷ 10 + 1) ÷ P abs

If O₂ counts as narcotic, it is the O₂ + N₂ sum that is limited: FO₂ + FN₂ = (END ÷ 10 + 1) ÷ P abs.

3. Helium fills the rest

FHe = 1 − FO₂ − FN₂. If nothing is left to fill, nitrox or air is enough.

4. Rounding on the safe side

Whole percentages are ordered: O₂ is rounded down (ppO₂ never exceeded), nitrogen too (END never exceeded), helium takes the rest. Exact values are shown in small under each gas.

5. Floor, MOD and density

Floor = (min ppO₂ ÷ FO₂ − 1) × 10, rounded up to the metre

If FO₂ is under the minimum ppO₂ (under 16 % O₂ with 0.16 bar), the mix is hypoxic: it cannot be breathed at the surface and needs a travel gas down to the floor.

MOD = (ppO₂ ÷ FO₂ − 1) × 10, rounded down to the metre

Density = P abs × (FO₂ × 1.429 + FN₂ × 1.251 + FHe × 0.179) g/L

Above 5.2 g/L the work of breathing rises sharply; 6.2 g/L is the generally accepted limit (Anthony and Mitchell, 2016).

6. Limiting density

By default, density is limited to 6.2 g/L: the tool removes nitrogen and adds helium until it holds ("Free" keeps only the warning). The actual END then becomes lower than your target.

FN₂ ≤ (max density ÷ P abs − FO₂ × 1.429 − (1 − FO₂) × 0.179) ÷ (1.251 − 0.179)

7. Standard gases

Many teams use a handful of common trimixes (21/35, 18/45, 15/55, 12/65, 10/70). The tool suggests the one with the least helium that meets all your limits.

Assumptions: sea level, sea water (10 m = 1 bar), air = 21 % O₂ + 79 % N₂, helium non-narcotic, gas densities at 0 °C (slightly conservative). A calculation aid: it replaces neither trimix training nor analysing the cylinder before the dive.

Understanding trimix blending

How do you choose a bottom trimix?

Start from the maximum depth. Oxygen is set by the ppO₂ accepted at depth (often 1.2 to 1.4 bar), nitrogen by the narcosis tolerated (the target END, often 30 m), and helium fills the rest. The result is rounded on the safe side: never above the requested ppO₂, END or density. To check the END of an existing mix, use the END tool.

Why limit gas density?

A dense gas takes more effort to breathe: CO₂ builds up, breathlessness looms and narcosis worsens. The Anthony and Mitchell guidelines (5.2 g/L recommended, 6.2 g/L maximum) are now used by several agencies, which plan first on ppO₂ and density. When the density limit decides, the tool adds helium and says so.

Hypoxic trimix and travel gas

Under 16 % oxygen (with a 0.16 bar floor), a trimix cannot be breathed at the surface: you descend on a travel gas down to the floor. The tool shows that floor, the usable range and the contingency MOD at 1.6 bar. For the maximum depth of a gas, see the MOD tool.

Frequently asked questions

Which trimix for 60 m?

With a ppO₂ of 1.4, an END of 30 m (oxygen not narcotic) and density limited to 6.2 g/L: Tx 20/38, at 6.15 g/L at depth. The nearest standard gas that meets these limits is 18/45.

How do you calculate the helium fraction?

FO₂ = max ppO₂ ÷ P abs, FN₂ = 0.79 × (END ÷ 10 + 1) ÷ P abs, and helium takes the rest: FHe = 1 − FO₂ − FN₂. Oxygen and nitrogen are rounded down.

What is a normoxic trimix?

A trimix with enough oxygen to be breathed at the surface (at least 16 % with a 0.16 bar floor, or 18 % for a cautious floor). Below that it is hypoxic and needs a travel gas.

Why 18/45 rather than the exact mix?

Standard trimixes (21/35, 18/45, 15/55, 12/65, 10/70) simplify filling and gas sharing within the team. They contain a little more helium than needed, but stay within all your limits.